And current best practice.
Roof ventilation requirements building regulations.
Roof voids must be ventilated in order to stop warm air condensing on cold surfaces.
There must be a slope of 1 80 part h of the building regulations regarding drainage state that water should drain to one or two edges waterproofing should extend up the adjacent walls at least 150mm from the roof surface cold roofs must have ventilation.
Be able to support loads weights provide resistance to heat loss insulation be ventilated to protect from condensation in most cases have adequate drainage.
Landscaping or gutters that direct water into or under the building.
Moisture problems may include.
Duo pitch roofs greater than 200 pitch or greater than 10m span should have additional ventilation at the ridge to assist airflow through the roof void equivalent to at least a 3 mm wide continuous gap.
Resist the spread of fire from one property to another.
Different areas have different safety regulations.
Jonathan taylor s article unpacks the key issues including the role of moisture ventilation and buffering.
Finding a roofer that is familiar with your area and the requirements will not only save you money in the long term but could also keep your family safe.
Published 1 december 2010 from.
Theinternational building code 2012 edition ibc 2012 requires enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing to have cross ventilation for each separate space.
Condensation encourages rot and mould growth.
The air gap dimensions shown on the drawings are the minimum widths required for clear continuous ventilation air paths at the eaves.
Around 25 per cent of heat loss occurs through a building s roof but high levels of insulation in historic roofs can be counter productive sometimes even accelerating heat loss in the long term.
Cold roofs versus warm roofs.
Building materials such as drywall may not allow moisture to escape easily.
Finding a roofing expert in your area is an important part of building a home that stands the test of time.
The net free vent area nfva shall not be less than 1 150 of the area of the space being vented.
To meet the requirements of the regulation one of the following systems should be employed.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.